Find help with thermal imaging of switchboards for Melbourne properties.

Switchboard thermal imaging in Derrimut

Thermal imaging of switchboards for Derrimut manufacturing, logistics and industrial sites in Brimbank, part of Melbourne's Western industrial precinct.

Derrimut, postcode 3026, is in the City of Brimbank in Melbourne’s west. It combines a growing residential area with industrial land that holds both long-established hazardous industries and newer manufacturing and logistics buildings. Switchboard thermal imaging enquiries from Derrimut businesses go through this site to independent providers, and the provider you choose is responsible for the scan, report and any repairs.

Derrimut’s place in the Western industrial precinct

Planning documents explain why. The state’s Melbourne Industrial and Commercial Land Use Plan calls the Western state-significant industrial precinct Melbourne’s largest, spread across Brimbank, Hobsons Bay, Maribyrnong, Melton and Wyndham. It names Derrimut as one of two locations in metropolitan Melbourne with Industrial 2 zoned land, designed for uses that need large buffer distances. The plan says Derrimut contains long-established hazardous uses as well as newer manufacturing and logistics uses that make use of the Western Ring Road.

Brimbank’s community profile describes the city as a growing residential area with substantial industrial and commercial areas, and lists Derrimut among the suburbs with the most recent residential growth. Construction is the largest employing industry in Brimbank, according to economy.id.

What that means for switchboards

Derrimut has two quite different kinds of industrial site:

Site type Electrical profile Scan focus
Long-established heavy industry Large main switchboards, high fault levels, motor control centres Busbar joints, large terminations, starters
Newer logistics warehouse Modern main board, lighting, dock doors, chargers, often rooftop solar Charger circuits, solar isolators, unbalanced phases
Newer manufacturing building Process plant added to a board sized for an earlier tenant Overloaded circuits, crowded boards
Mixed showroom and workshop Smaller board with several sub-boards Additions over time

Heavy industrial sites with buffer requirements often have strict entry rules and permits. A provider will need to know the site’s safety procedures before quoting. For high-energy boards, ask how the provider manages arc flash risk under AS/NZS 4836, the standard for safe work on or near low voltage installations.

Solar on logistics roofs

Where a warehouse roof carries a solar array feeding the main board, the inverter and isolators need attention too. Energy Safe Victoria recommends solar systems be serviced every 2 years by a licensed electrician. A thermal check of inverters and isolators fits well with that service; see the solar inverter and battery thermal check page.

Typical Derrimut requests

  • an annual switchboard thermal imaging scan for the insurer
  • a pre-lease or end-of-lease scan when a warehouse changes tenant
  • a plant survey after a new production line is added to an existing board
  • a re-scan after repairs to close out last year’s findings

Rental homes in the suburb

Derrimut’s residential side has grown alongside its industry. Landlords there have a separate duty: Consumer Affairs Victoria says rental providers must have all electrical installations, fixtures and fittings checked by a licensed or registered electrician every 2 years, following section 4 of AS/NZS 3019. A thermal image of the home’s switchboard is not required by that rule, though some electricians offer one alongside the check.

Access and timing

  • Logistics sites often run around the clock, so a scan can be timed to the busiest dispatch period
  • Hazardous industry sites may require a site-specific induction, gas detection or a permit to work
  • Boards in large warehouses can be spread across the building, so a site plan saves time
  • Forklift traffic and racking may limit how close a vehicle or ladder can get to a board

Repairs and cost

Repair work on large industrial boards usually needs a planned shutdown, which the hot spot repair and re-scan page covers, including the Certificate of Electrical Safety you should receive. Published Melbourne electrician rates and switchboard upgrade ranges are in the cost guide.

Next step

Gather the site’s induction requirements, the number of boards and any solar details, then submit a Derrimut thermal imaging enquiry so an independent provider can respond about scope and timing.

Send a job enquiry

Frequently asked questions

Are there extra rules for scanning on hazardous industry sites?

Sites with hazardous uses usually have their own entry, permit and gas detection procedures. The provider must follow them, so send them through before the quote is prepared.

Is thermal imaging part of a rental electrical safety check?

No. The two-yearly check for rental homes follows AS/NZS 3019 and is done by a licensed or registered electrician. A thermal image of the board can be added if the electrician offers it.

When should a warehouse be scanned?

During its busiest period, such as peak dispatch or when chargers, dock doors and lighting are all running. A quiet period can hide faults that show under full load.

Can a scan be done at the end of a warehouse lease?

Yes. A scan at handover gives landlord and outgoing tenant a shared record of the boards' condition, which can help settle questions about wear and damage.